Brand Name : P+F
Model Number : KFD2-UT2-1
Certification : CE
Place of Origin : Germany
MOQ : 1 piece
Price : negotiable
Payment Terms : T/T
Supply Ability : 100pcs per month
Delivery Time : on request
Packaging Details : standard carton packing
Labeling : space for labeling at the front
Safety Integrity Level (SIL) : SIL 2
Degree of protection : IEC 60529:2001
Supply Connection : terminals 14+, 15- or power feed module/Power Rail
Ambient temperature : -20 ... 60 °C (-4 ... 140 °F)
Dimensions : 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple
Technical Data
|   			 General specifications  |   		||
|---|---|---|
|   			 Signal type  |   			  			 Analog input  |   		|
|   			 Functional safety related parameters  |   		||
|   			 Safety Integrity Level (SIL)  |   			  			 SIL 2  |   		|
|   			 Supply  |   		||
|   			 Connection  |   			  			 terminals 14+, 15- or power feed module/Power Rail  |   		|
|   			 Rated voltage  |   			  			 20 ... 30 V DC  |   		|
|   			 Ripple  |   			  			 within the supply tolerance  |   		|
|   			 Power dissipation  |   			  			 ≤ 0.98 W  |   		|
|   			 Power consumption  |   			  			 max. 0.98 W  |   		|
|   			 Interface  |   		||
|   			 Programming interface  |   			  			 programming socket  |   		|
|   			 Input  |   		||
|   			 Connection side  |   			  			 field side  |   		|
|   			 Connection  |   			  			 terminals 1, 2, 3, 4  |   		|
|   			 RTD  |   			  			 type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)  |   		|
|   			 
  |   			  			 Measuring current  |   			  			 approx. 200 µA with RTD  |   		
|   			 
  |   			  			 Types of measuring  |   			  			 2-, 3-, 4-wire connection  |   		
|   			 
  |   			  			 Lead resistance  |   			  			 max. 50 Ω per line  |   		
|   			 
  |   			  			 Measurement loop monitoring  |   			  			 sensor breakage, sensor short-circuit  |   		
|   			 Thermocouples  |   			  			 type B, E, J, K, N, R, S, T (IEC 584-1: 1995)  |   		|
|   			 
  |   			  			 Cold junction compensation  |   			  			 external and internal  |   		
|   			 
  |   			  			 Measurement loop monitoring  |   			  			 sensor breakage  |   		
|   			 Potentiometer  |   			  			 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)  |   		|
|   			 Voltage  |   			  			 selectable within the range -100 ... 100 mV  |   		|
|   			 Input resistance  |   			  			 ≥ 1 MΩ (-100 ... 100 mV)  |   		|
|   			 Output  |   		||
|   			 Connection side  |   			  			 control side  |   		|
|   			 Connection  |   			  			 output I: terminal 7: source (-), sink (+), terminal 8: source (+), terminal 9: sink(-)  |   		|
|   			 Output  |   			  			 Analog current output  |   		|
|   			 
  |   			  			 Current range  |   			  			 0 ... 20 mA or 4 ... 20 mA  |   		
|   			 
  |   			  			 Fault signal  |   			  			 downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)  |   		
|   			 
  |   			  			 Source  |   			  			 load 0 ... 550 Ω  |   		
|   			 
  |   			  			 Sink  |   			  			 Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,  |   		
|   			 Transfer characteristics  |   		||
|   			 Deviation  |   			  			 
  |   		|
|   			 
  |   			  			 After calibration  |   			  			 Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection))  |   		
|   			 
  |   			  			 Influence of ambient temperature  |   			  			 Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)  |   		
|   			 
  |   			  			 Influence of supply voltage  |   			  			 < 0.01 % of span  |   		
|   			 
  |   			  			 Influence of load  |   			  			 ≤ 0.001 % of output value per 100 Ω  |   		
|   			 Reaction time  |   			  			 worst case value (sensor breakage and/or sensor short circuit detection enabled)  |   		|
|   			 Galvanic isolation  |   		||
|   			 Input/Other circuits  |   			  			 basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff  |   		|
|   			 Output/supply, programming input  |   			  			 functional insulation, rated insulation voltage 50 V AC  |   		|
|   			 Indicators/settings  |   		||
|   			 Display elements  |   			  			 LEDs  |   		|
|   			 Configuration  |   			  			 via PACTware  |   		|
|   			 Labeling  |   			  			 space for labeling at the front  |   		|
|   			 Directive conformity  |   		||
|   			 Electromagnetic compatibility  |   			  			 
  |   		|
|   			 
  |   			  			 Directive 2014/30/EU  |   			  			 EN 61326-1:2013 (industrial locations)  |   		
|   			 Conformity  |   		||
|   			 Electromagnetic compatibility  |   			  			 NE 21:2006  |   		|
|   			 Degree of protection  |   			  			 IEC 60529:2001  |   		|
|   			 Ambient conditions  |   		||
|   			 Ambient temperature  |   			  			 -20 ... 60 °C (-4 ... 140 °F)  |   		|
|   			 Mechanical specifications  |   		||
|   			 Degree of protection  |   			  			 IP20  |   		|
|   			 Connection  |   			  			 screw terminals  |   		|
|   			 Mass  |   			  			 approx. 130 g  |   		|
|   			 Dimensions  |   			  			 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2  |   		|
|   			 
  |   			  			 Height  |   			  			 119 mm  |   		
|   			 
  |   			  			 Width  |   			  			 20 mm  |   		
|   			 
  |   			  			 Depth  |   			  			 115 mm  |   		
|   			 Mounting  |   			  			 on 35 mm DIN mounting rail acc. to EN 60715:2001  |   		|
Related Models:
|   			 KCD2-SCD-EX1  |   			  			 KFU8-UFT  |   		
|   			 KCD2-STC-EX1.20  |   			  			 K-HM26-2M-261533  |   		
|   			 KFD2-SR2-Ex1.W.LB  |   			  			 NBB15-U1-E2  |   		
|   			 KFD2-SR2-2.W.SM  |   			  			 NBB1,5-5GM25-E2  |   		
|   			 KFD2-SR2-Ex2.W.SM  |   			  			 NBB1,5-5GM25-E2-V3  |   		
|   			 KFD2-SR2-Ex2.2S  |   			  			 NBB1,5-F79-E0  |   		
|   			 KFD2-SR2-2.2S  |   			  			 NBB1,5-F79-E2  |   		
|   			 KFA6-DWB-EX1.D  |   			  			 NBB15-U1-Z2  |   		
|   			 KFA6-SR2-Ex2.W  |   			  			 NBB5-18GM50-E2-V1  |   		
|   			 KFA6-SR-2.3L.FA  |   			  			 NBB15-30GM30-E2-V1  |   		
|   			 KFA6-ER-1.5  |   			  			 NBB15-30GM50-A2-V1  |   		
|   			 NBB15-30GM50-E2  |   		|
|   			 KFA6-ER-1.W.LB  |   			  			 NBB15-30GM50-E2-M  |   		
|   			 KFA6-ER-2.W.LB  |   			  			 NBB15-30GM50-E2-V1  |   		
|   			 NBB15-30GM50-E2-V1-M  |   		|
|   			 KFA6-SR-2.3L.FA  |   			  			 NBB8-18GM30-E2  |   		
|   			 KFA6-STR-1.24.4  |   			  			 NBB8-18GM30-E2-V1  |   		
|   			 KFD0-CS-Ex1.50P  |   			  			 NBB8-18GM60-A2-V1  |   		
|   			 KFD2-SH-Ex1.T.OP  |   			  			 NJ4-12GK-SN  |   		
|   			 KFD2-SL2-EX2.B  |   			  			 NJ5-18GK-N  |   		
|   			 KFD2-SR2-EX1.W  |   			  			 NJ5-18GK-N-150  |   		
|   			 KFD2-SR2-Ex2.W  |   			  			 NJ5-18GM-N  |   		
|   			 KFD2-STC5-1.2O  |   			  			 NJ8-18GK-N  |   		
|   			 KFD2-STC5-Ex1  |   			  			 RD0-FB-EX4  |   		
|   			 KFD2-STC5-Ex1.H  |   			  			 RD0-TI-Ex8.FF.*  |   		
|   			 HIC2031  |   			  			 Z787.F  |   		



| 
                                             | 
                